MECER 1200VA 720W 12V Inverter
R2,290.00 incl vat
(Not Compatible with Lithium Batteries)
Mecer has been one of South Africa’s top-selling PCs over the past two decades. Mustek’s ongoing interaction within the international IT industry has ensured that Mecer has remained a techno-leader at the forefront of technology.
Please note that batteries are not included and needs to be bought separately
This unit is also intended for use with IT equipment and will not be able to run a kettle, heater or anything that uses a motor or an element.
Features:
– Simulated sine wave inverter
– Built-in AVR for voltage regulation
– Wide input voltage range: 90-280 VAC
– 12VDC available
– Overload and short circuit protection
– LCD display for comprehensive information
Specifications:
– MODEL Mecer IVR-1200LBK
– CAPACITY 1200 VA / 720 W
– POWER FACTOR 0.8
– Input Voltage range 90-280VAC
Line Mode:
– Output Voltage
– Bypass mode: 0utput voltage same as input voltage
– AVR mode: Output voltage = Input voltage 1.2 at Input voltage – Output Frequency Same as input
Battery Mode (BATTERIES NOT INCLUDED):
– Output Voltage 230Vac +/-10%
– Transfer Time 20ms typical
– Waveform Modified Sine-wave
Overload Capability:
– Bypass Mode (in VA and Watts) Load >110%+/-15% , alarm 5 mins then fault
– Load >130% +/-15%, fault immediately.
– AVR Mode (in VA and Watts)at Input voltage > 170VAC Load >100%+/-15%, go to bypass mode
– AVR Mode (in VA and Watts)at Input voltage < 170VAC Load >60%+/-15%, go to bypass mode
– Battery Mode (in W) Load>110% +/-15%, overload alarm for 15s, and then will switch to fault mode for 10s. Then unit will re-start for 5 times Load>120% +/-15% , fault & cut off O/P immediately.
Short Circuit Protection:
– Line Mode Breaker
– Battery Mode Current limit +Firmware Protection
Battery specs needed (NOT INCLUDED):
– Battery Voltage 12VDC
– Acceptable Battery Type Rechargeable lead-acid battery, Deep discharge battery
– Polarity Reserve Protection Yes
– Charger available I/P range 90 280V
Charger:
– Constant Current Charger Voltage 14.3VDC +/-2%
– Floating Charge Voltage 13.7VDC +/-2%
– Maximum Charge Current 10A or 20A
– DC Start Voltage >11VDC
Physical:
– Dimension, D X W X H (mm) 350 x 90 x 300
– Net Weight (kgs) 4.5
Environment:
– Operating Humidity 0 to 90% Relative Humidity(Non-condensing)
– Operating Temperature 0 degrees C to 40 degrees C
– Storage Temperature -15 degrees C to 50 degrees C